V3F
Max height m 10,25
Suitable for heavy duty
Three-section push-up ladder with rope, base stabiliser, non-skid rubber feet, extension blocking device
Professional fiberglass ladders suitable for those operators who work next to cables, outlets or other electric energy sources. The fiberglass frames assure electric insulation but our ladders are also light and easy to manage thanks to the non-skid knurled aluminium rungs.
Three-section push-up ladder with rope.
STANDARD OUTFITS
• Sliding wheels
• Base stabiliser
• Adjustable wrench for stabiliser fastening
• Instructions for assembly and use
• Nylon reinforcement inside stabiliser seat
• Aluminium opening system
• Strap preventing uncontrolled ladder opening
• Non-skid rubber feet
• Device to stop upward movement
• Extension blocking device
• Capacity 150 kg
• Step distance 28 cm
• Rungs section 27x27 mm
• Base section width 49 cm
• Intermediate section width 42 cm
• Final section width 36 cm
• Thermo-shrinkable plastic package with showcard
It is equipped with sliding wheels, base stabiliser and triple pulley for rope control.
Very important: this model cannot be used as a stepladder.
With a minimum extension of 40 cm of the third section.
Very important: A.m. results are obtained with new ladder and fine weather.
Three-section push-up ladder with rope.
STANDARD OUTFITS
• Sliding wheels
• Base stabiliser
• Adjustable wrench for stabiliser fastening
• Instructions for assembly and use
• Nylon reinforcement inside stabiliser seat
• Aluminium opening system
• Strap preventing uncontrolled ladder opening
• Non-skid rubber feet
• Device to stop upward movement
• Extension blocking device
• Capacity 150 kg
• Step distance 28 cm
• Rungs section 27x27 mm
• Base section width 49 cm
• Intermediate section width 42 cm
• Final section width 36 cm
• Thermo-shrinkable plastic package with showcard
It is equipped with sliding wheels, base stabiliser and triple pulley for rope control.
Very important: this model cannot be used as a stepladder.
With a minimum extension of 40 cm of the third section.
Very important: A.m. results are obtained with new ladder and fine weather.
EUROPEAN STANDARD CEI EN 50528:
The V3F fiberglass ladder complies with Standard EN 50528 which concerns ladders used for work on low voltage live parts such as making connections, work on supports and switching operations.
These ladders are also used for preliminary operations for live work such as checking the voltage, earthing and short-circuiting, etc.
The purpose of this Standard is to provide ladders that have two main functions: access to the parts of the system on which work must be done and protect the worker from electrical risks by providing the level of insulation and maintaining a safety distance between the operator and the potentially live parts of the system.
It concerns insulating ladders for use on low voltage systems or in their proximity.
This Standard, which complies with EN 61477, must be used in accordance with Standards EN 50110-1 and EN 50110-2.
This Standard is published by CEI in English only as it is particularly aimed at specialized sectors.
This Standard remains applicable until 29-04-2027.
The tests are carried out with an electric charge of 36,000 Volts for one minute.
These ladders are also used for preliminary operations for live work such as checking the voltage, earthing and short-circuiting, etc.
The purpose of this Standard is to provide ladders that have two main functions: access to the parts of the system on which work must be done and protect the worker from electrical risks by providing the level of insulation and maintaining a safety distance between the operator and the potentially live parts of the system.
It concerns insulating ladders for use on low voltage systems or in their proximity.
This Standard, which complies with EN 61477, must be used in accordance with Standards EN 50110-1 and EN 50110-2.
This Standard is published by CEI in English only as it is particularly aimed at specialized sectors.
This Standard remains applicable until 29-04-2027.
The tests are carried out with an electric charge of 36,000 Volts for one minute.