V2FC Ladder with 2-trunk rope 100% fiberglass
Ladder with 2-section rope 100% in dielectric fiberglass (uprights/rungs) only leaning against the wall for applications in electrical, food, chemical, brackish environments.
They are built with both rungs and fiberglass uprights.
- Scroll wheels on the wall
- Anti-slip hook
- Base spreader
- Rope with pop-up and pulley
- Last 3 red safety rungs (not walkable). The operator must remain with his feet under the red rungs.
- 30 mm non-slip rungs. Distance between rungs: 28 cm.
- Operation and maintenance manual
- Upright profile 70x28 mm
- Identification label
- Antimagnetic and resistant to moisture, acids, corrosion and ultraviolet rays.
Screws and metal parts in stainless steel.
- Yellow belt to support the pole (optional)
- Adjustable telescopic legs (optional)
| Model | Pegs Number | Height closed m | Height open m | Upright profile mm | Weight Kg |
FIBRAFC10 | 2X10 | 3,01 | 4,89 | 70x28 mm | 24 |
FIBRAFC11 | 2X11 | 3,29 | 5,45 | 70x28 mm | 25,5 |
FIBRAFC12 | 2X12 | 3,57 | 6,01 | 70x28 mm | 27 |
FIBRAFC13 | 2X13 | 3,85 | 6,57 | 70x28 mm | 28,5 |
FIBRAFC14 | 2X14 | 4,13 | 7,13 | 70x28 mm | 30 |
FIBRAFC15 | 2X15 | 4,41 | 7,69 | 82x32 | 38 |
FIBRAFC16 | 2X16 | 4,69 | 8,25 | 82x32 | 40 |
FIBRAFC17 | 2X17 | 4,97 | 8,81 | 82x32 | 42 |
FIBRAFC18 | 2X18 | 5,25 | 9,37 | 82x32 | 44 |
FIBRAFC19 | 2X19 | 5,53 | 9,93 | 82x32 | 46 |
REGULATIONS
The V2FC ladder series has been successfully tested according to the following standards:
- EN 131-1: 2015+A1:2019 + A2:2025
- EN 131-2: 2010 + A1:2012 + A2:2017 + A3:2025
- EN 131-3: 2018 + A1:2025
Insulating ladder for electrical work – Tested according to EN 61478 up to 30 kV.
Designed for professional applications in the electrical sector, this insulating ladder has passed the tests required by the EN 61478 standard (Live working – Ladders of insulating material), according to the requirements and test conditions applicable up to 30 kV, as documented by the relevant test reports.
EN 61478 is specifically dedicated to ladders made of insulating material intended to facilitate access when working on live electrical systems.
Passing the documented tests attests to the verified performance of the product under the specific test conditions envisaged.
The ladder is intended only for qualified personnel, trained in electrical work, and must be used in compliance with safety procedures, the manufacturer's instructions and the intended operating conditions.
Compliance with EN 61478 tests: documented by test report.
Declared test level: up to 30 kV, within the limits and according to the methods indicated in the technical documentation of the product.
The product may only be used near low-voltage electrical installations.