V2E 2-section ladder 100% fiberglass

Max height 6.08 m
Suitable for heavy duty

2-section ladder 100% in dielectric fiberglass (uprights/rungs) for applications in electrical, food, chemical, brackish environments.

V2E is 100% FIBERGLASS (UPRIGHTS AND RUNGS)
It is a series of professional ladders with 2 trunks that can be used as an extension and/or trestle, available in manual and rope versions.
They are built with both rungs and fiberglass uprights.
They are suitable for operators who are working near cables, sockets or other sources of electricity.
Also suitable for special uses in areas with high electrical or food or chemical hazards where aluminium cannot enter.
 
STANDARD EQUIPMENT
  • Non-slip rubber feet
  • Base spreader
  • Operation and maintenance manual
  • Identification label
  • Stainless steel accessories and hinges.
 
SPECIFICATIONS
Model Height Height Width Weight Working height
lock Open  stretcher Kg wall-mounted trestle
m m Mm   m m
FC06 1,76 2,72 650 15 3,54 2,50
FC07 2,06 3,28 700 16,5 4,12 2,75
FC08 2,34 3,84 740 18 4,70 3,05
FC09 2,66 4,40 780 19,5 5,24 3,30
FC010 2,94 4,96 830 21 5,80 3,60
FC011 3,22 5,52 870 22,5 6,30 3,90
FC012 3,50 6,08 920 24 6,80 4,15
 

STANDARDS

The V2FCO ladder series has been successfully tested according to the following standards:

  • EN 131-1: 2015 + A1:2019 + A2:2025
  • EN 131-2: 2010 + A1:2012 + A2:2017 + A3:2025
  • EN 131-3: 2018 + A1:2025

 

EUROPEAN STANDARD EN 61478 UP TO 30 kV:

  • Insulating ladder for electrical work – Tested according to EN 61478 up to 30 kV.

Designed for professional applications in the electrical industry, this insulating ladder has passed the tests required by the EN 61478 standard (Live working – Ladders of insulating material), according to the applicable requirements and test conditions up to 30 kV, as documented in the relevant test reports.

EN 61478 is specifically designed for ladders made of insulating material intended to facilitate access during work on live electrical systems.

Passing the documented tests certifies the product's verified performance under the specific test conditions.

The ladder is intended exclusively for qualified personnel trained in electrical work and must be used in compliance with safety procedures, the manufacturer's instructions, and the intended operating conditions.

Compliance with EN 61478 tests: documented by a test report.

Declared test level: up to 30 kV, within the limits and according to the methods indicated in the product's technical documentation.

  • The product is permitted for use only near low-voltage electrical systems.
 
Do you need more information?
Our experience is at your service to support you and recommend the right product.
One of our experts will contact you without any obligation.